Compressed Air Filters

                                                                            types of filters

                                                                                            Particulate filters

Particulate compressed air filters are used to remove dust and particles from the air.

Activated carbon filters

filters utilize a composite carbon material to remove gases and odors from the air.

Coalescing filters

High oil compressed air coalescing filters remove water and oil aerosols by coalescing the aerosols into droplets

Compressed intake filters

Intake filters are the first line of defense in filtering. These filters can remove contaminates down to 0.3 µm and can remove chemical contaminants.



TECHNICAL AND MEDICAL GASES

Compressed air for utilisation as breathing air in the medical technology sector is subject to special requirements. A reliable provision of human beings with breathing air entails a high level of responsibility. Compressed air as breathing air for patients is defined in the updated European Pharmacopoeia.
For the sensitive application of breathing air purification in the medio-technical field, Parker Zander commissioned an independent institute with tests of the breathing air purification unit in terms of regard to compliance with the maximum allowable concentrations and stability of oxygen concentration. With the validation certificate Parker Zander confirms compliance with the stipulated maximum allowable concentrationion.
  • Breathing air in the medical technology sector is subject to special requirements
  • the series BSP-MT as solution for ultrapure medical breathing air 
  • with a validation certificate from an independent institute Parker Zander confirms compliance with the maximum allowable concentrations  
  • residual values as per "European Pharmacopoeia", Parker Zander BSP-MT is clearly below the threshold values
  • service life time: filter elements: 8000 operating hours, desiccant: 4000 operating hours
  • flow capacity of up to 6000 m³/h (option)
  • pressure stages of up to 100 bar (option). Other pressure stages on request
  • dew point dependent control (option)
Maximum allowable concentrations for medical air
"European Pharmacopoeia"
Parker Zander BSP-MT
Carbon monoxide
< 5 ppm
< 2 ppm
Carbon dioxide
< 500 ppm
< 150 ppm
Water vapour
< 67 ppm
< 15 ppm
Suphur dioxide
< 1 ppm
< 0,1 ppm
Nitrouse gases
< 2 ppm
< 1 ppm
Oil components
< 0,1 mg/m³
< 0,003 mg/m³
Oxygen Concentration
20,4 - 21,4 %
20,8 - 21,1 %
Odour and flavour substances
free
free



Direct links to other Parker Hiross Zander products that might be interesting
Compressed air filtration: compressed air filtershigh pressure compressed air filterssilicon free compressed air filterscartridge filters and point of use dryers Compressed air dehumidification: refrigeration dryers (including high pressure units), adsorption dryers (including high pressure and heat regenerated dryers)medical breathing air systemsoil vapour adsorbers Condensate management: water separatorscentrifugal separatorscondensate drains (electronic zero loss drains, timed drains, mechanical float drains), oil-water separators Precision water cooling: watercooling chillersdrycoolerschillers for laser applications Compressed air cooling: air cooled aftercoolerswater cooled aftercoolers CNG and gas treatment: chillers, coolers and condensate drains for BiogasCNG filtershigh pressure CNG filterssingle tower gas adsorbersfilters for industrial gaseshigh pressure filters for industrial gases Aftermarket: Parker Hiross 
Zander aftermarket information

MEDICAL GAS MANIFOLDS

Perfect function, simple control

Gas manifolds are designed to supply the pipeline system with sufficient quantity of gas by cylinders and/or tanks. The typical manifold for medical gases (oxygen, nitrogen, CO2 or medical air) according to EN ISO 7396-1 or HTM 02-01 usually consists of a two-sided cylinder supply with automatic changeover between the empty and full side, and an additional third source for emergency supply. For oxygen, the liquid source is usually used as the primary supply, while the two-side cylinder supply is used for reserve. The design of Medicop manifolds enables highly reliable functioning and offers a number of advantages for the user; for example:

Multifunction

We have models available for the whole range of users, from small clinics with one terminal unit for gas, up to the biggest health-care institutions with thousands of terminal units.

Integrated digital display

All information about manifold status (pressure level of each source, line pressure level) and warnings are monitored on one display, which also supports forwarding of collected information for central supervision of medical gas supply.

Eesy handling

The special conical shape of cylinder connection and handle fixed on all connecting points allows all empty cylinders to be changed without tools.

Easy maintenance

Filters and other disposable components are  easily accessible, so regular service can be carried out in a very short time.

Universal compatibility

Valves for cylinder connections are available in all standards for high-pressure equipment in use around the world.

Uninterrupted flow

Double line-pressure regulators and NIST inlets make it possible for pipelines to be supplied with the required quantity of gas even during maintenance or service of any component of a manifold.

Safety by design

Special safety valves are installed for each source of high pressure, as well as a separate safety valve for line pressure.

AVAILABLE OPTIONS    
Capacity  50 m3/h
100 m3/h
180 m3/h
Number of cylinders1–48
Display of status/alarmanalogue by gauges,
digital with central LCD
Type of gasOxygen, Nitrous Oxide, Carbon Dioxide, Air, Nitrogen, Helium
Available standardsEN ISO 7396-1 or HTM 02-01